Control Panels
A pump control panel is used at pump installations to automatically operate a pump according to sump chamber level, water supply pressure level or tank level within a water supply tank.
Pump control panels equipped with motor-protection and dry run protection are designed to prevent damage of the electric pump-motor and allow monitoring of the pump installation via the associated alarm output.
Pump control panels are available for both single-phase 230V/50Hz as well as for 3-phase 400V/50Hz electric power supply.
Single Pump Control Panel
A pump operated according to "duty standby" is connected to a control panel for one pump. An external switching device such as a float switch or pressure switch is connected to the the single pump control panel, activating / deactivating the pump according to the sump chamber level or water supply pressure.
Remote Pump Monitoring System
In the event of an alarm, this is displayed by the pump control panel display and alarm output(s). The alarm output enables monitoring of the pump installation on-site as well as remotely via building management system (BMS). This is required in order to ensure an efficient and expeditious response to the disruption at the pump installation.
2 Pump Control Panel
A twin pump control panel according to "duty standby assist" operates two pumps within the sump chamber or water supply reservoir such as a rainwater harvesting tank. The significant advantages of a two pump control panel with "duty standby assist" lie within the enhanced operational safety and ability to operate both pumps simultaneously, when required.
Duty Standby Assist
In the event of an alarm at one unit, the remaining pump continues operation, whilst the alarm output informs the building management system of the disruption. Especially at installations where continued pump operation is required at all times, a dual pump setup provides improved operational safety.
Duplex Alternating Pump Control Panel
The duplex alternating pump control panel switches the pump after each pumping cycle but also allows to activate the non-operational pump additionally in order to assist during times of peak demand.
For this, 2x external switching devices (float switch / pressure switch) are connected to the two pump control panel to define standard operation and peak load.
Pump Control Panel for the operation of 1x Pump | Duty/Standby230V | 1Ph |50 Hz | kW: 0.25 - 1.5 / A: 1.0 - 11.0 - IP 64 Dimensions: 175 x 200 x 100 mm Automatic operation with connected pressure-switch or float-switch. Manual operation possible. Digital display for operating conditions and Error-messages. Cable connections: 4 x M20 (mains supply, pump, pressure-switch/float-switch, alarm) ON/OFF Switch Overload Protection, Short Circuit Protection, Phase-malfunction protection Dry run protection via power factor COS-phi Automatic Learning Program for pump parameters after start-upPump parameters + number of restarts with in between time-intervals can be manually altered Alarm Output: potential-free for BMS (max. 230V/4.0A) Integrated connection possibility for pump capacitor (optional)CE | WEEE | Made in Germany The EBARA Econtrol Classic 230 is a pump control panel for 1x single-phase pump in 230V/50Hz with a maximum power output of 0.25kW to 1.50kW or electric current consumption from 1.0A to 11.0A. Automatic Pump Operation via external switch The pump control panel is equipped with 2x input connections (marked "Schwimmer") to which an external pressure-switch, float switch or other external switching device can be wired. Once the contacts are closed the pump will automatically start operation. The pumping cycle ceases once the contact is opened again. Integrated Learning Program on Start-Up The panel has an integrated learning program which detects the power rating of the electric pump motor and automatically sets threshold values for motor-protection and pump dry run protection. All pump parameters including the number of restarts after detected dry run and the time interval in between each renewed attempt can be adjusted. Applications sump pump wastewater treatment system pump well pump rainwater harvesting pump; only direct-pressurised setup The control panel can be used to automatically operate a drainage sump pump or effluent pump of a wastewater treatment system or septic tank via an electric level float switch inside the sump chamber. Especially for a borehole well pump installation the EBARA Econtrol Classic is of benefit. The integrated dry run protection via the electric power factor COS-phi resolves the issue of not being able to install a low level float switch inside the deep borehole. In addition, for single-phase borehole pumps with external capacitor the panel has electric contacts available (optional) in order to integrate the pump capacitor into the pump control panel for easy access. Automatic pump operation for a well water installation can be provided by connecting a pressure-switch or float-switch to the panel. The EBARA Econtrol Classic pump control panel can also be used at rainwater harvesting installations where mains-water top-up is provided to the underground rainwater storage tank. Alarm Output to BMS Should motor-protection or dry run protection be activated, the potential-free alarm output to the building management system (BMS) is closed, prompting an external alarm display in addition to the digital display of the panel. Alternatively, the alarm output could also be used to activate an external alarm-light/buzzer/siren (max. 230V/4.0A).
Pump Control Panel for the operation of 1x Pump | Duty/Standby 400V | 3Ph | 50 Hz | kW: 0.5 - 4.0 / A: 1.0 - 11.0 - IP 64 Dimensions: 175 x 200 x 100 mm Automatic operation with connected pressure-switch or float-switch. Manual operation possible. Digital display for operating conditions and Error-messages. Cable connections: 4 x M20 (mains supply, pump, pressure-switch/float-switch, alarm) ON/OFF Switch Overload Protection, Short Circuit Protection, Phase-malfunction protection Dry run protection via power factor COS-phi Automatic Learning Program for pump parameters after start-upPump parameters + number of restarts with in between time-intervals can be manually altered Alarm Output: potential-free for BMS (max. 230V/4.0A) CE | WEEE | Made in Germany The EBARA Econtrol Classic 400 A is a pump control panel for 1x three-phase pump in 400V/50Hz with a maximum power output of 0.50kW to 4.0kW or electric current consumption from 1.0A to 11.0A. Automatic Pump Operation via external switch The pump control panel is equipped with 2x input connections (marked "Schwimmer") to which an external pressure-switch, float switch or other external switching device can be wired. Once the contacts are closed the pump will automatically start operation. The pumping cycle ceases once the contact is opened again. Integrated Learning Program on Start-Up The panel has an integrated learning program which detects the power rating of the electric pump motor and automatically sets threshold values for motor-protection and pump dry run protection. All pump parameters including the number of restarts after detected dry run and the time interval in between each renewed attempt can be adjusted. Applications sump pump wastewater treatment system pump well pump rainwater harvesting pump; only direct-pressurised setup The control panel can be used to automatically operate a drainage sump pump or effluent pump of a wastewater treatment system or septic tank via an electric level float switch inside the sump chamber. Especially for a borehole well pump installation the EBARA Econtrol Classic is of benefit. The integrated dry run protection via the electric power factor COS-phi resolves the issue of not being able to install a low level float switch inside the deep borehole. Automatic pump operation for a well water installation can be provided by connecting a pressure-switch or float-switch to the panel. The EBARA Econtrol Classic pump control panel can also be used at rainwater harvesting installations where mains-water top-up is provided to the underground rainwater storage tank. Alarm Output to BMS Should motor-protection or dry run protection be activated, the potential-free alarm output to the building management system (BMS) is closed, prompting an external alarm display in addition to the digital display of the panel. Alternatively, the alarm output could also be used to activate an external alarm-light/buzzer/siren (max. 230V/4.0A).
Pump Control Panel for the operation of 1x pump | Duty Standby230V | 1Ph | 50 Hz | max. P2: > 0.75 kW | A: 4.0 - 6.3 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with connected Pressure-Switch or Float-Switch Manual Pump Operation possible Dry-Run Protection with connected Float-Switch (low level)Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm)1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Single Pump Control Panel in 230V with motor-protection and "duty standby" to automatically operate 1 pump (with a current rating of 4.0-6.3A). The pump panel is used in sump chamber installations and water supply systems. Sump Pump Control Panel | Duty Standby A pump control panel with "duty standby" to automatically switch a submersible sump pump or water supply pump at wells or rainwater harvesting installations. Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Once the contact is opened pump operation ceases. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the single pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 1x pump | Duty Standby230V | 1Ph | 50 Hz | max. P2: > 1.10 kW | A: 6.3 - 10.0 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with connected Pressure-Switch or Float-Switch Manual Pump Operation possible Dry-Run Protection with connected Float-Switch (low level)Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm)1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Single Pump Control Panel in 230V with motor-protection and "duty standby" to automatically operate 1 pump (with a current rating of 6.3-10.0A). The pump panel is used in sump chamber installations and water supply systems. Sump Pump Control Panel | Duty Standby A pump control panel with "duty standby" to automatically switch a submersible sump pump or water supply pump at wells or rainwater harvesting installations. Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Once the contact is opened pump operation ceases. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the single pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 2x pumps | Duty Standby Assist 230V | 1Ph | 50 Hz | max. P2: > 0.75 kW | A: 4.0 - 6.3 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with 2x connected Pressure-Switches /Float-Switches (Operation + Peak Load) Manual Pump Operation for each pump possible Alternating Duty: pump switch-over after each pumping cycle (equal operational hours for both pumps) Dry-Run Protection with connected Float-Switch (low level); contacts bridged ex works Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm for each pump Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm) 1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Twin Pump Control Panel in 230V with motor-protection and "duty standby assist" to automatically operate 2 pumps (each with a current rating of 4.0-6.3A). The dual pump panel is used in sump chamber installations and water supply systems where enhanced operational safety is required. Twin Sump Pump Control Panel | Duty Standby Assist A pump control panel with "duty standby assist" offers signficantly greater flexibility and uses the full potential of a dual pump installation setup. This allows to cover the performance level for standard operation as well as unusual high demand during e.g. freak precipitation events (drainage sump chamber) or higher water-supply demand (rainwater harvesting system). Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Duplex Alternating Pump Control Panel The dual pump control panel switches 2 pumps with alternating duty. The automatic switch-over after each pumping cycle ensures both pumps are used equally. In the event that motor-protection of one pump is triggered, the automatic supply is upheld with the remaining pump. Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Only one pump is in operation, while the other pump remains switched off. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Pump | Assist | Peak Load In order to use the remaining non-operative pump as backup support, the contacts marked "Peak Load" are available to connect an additional external switch (e.g. pressure switch or float switch). If the contacts are closed by the external switch device, the 2nd pump in standby is activated additionally to assist the 1st pump. The assist function via the contacts "Peak Load" is an optional extra and does not have to be used! Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Pressure Switch / Float Switch; Peak Load Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED for respective pump & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the dual pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 2x pumps | Duty Standby Assist 230V | 1Ph | 50 Hz | max. P2: > 1.1 kW | A: 6.3 - 10.0 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with 2x connected Pressure-Switches / Float-Switches (Operation + Peak Load) Manual Pump Operation for each pump possible Alternating Duty: pump switch-over after each pumping cycle (equal operational hours for both pumps) Dry-Run Protection with connected Float-Switch (low level); contacts bridged ex works Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm for each pump Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm) 1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Twin Pump Control Panel in 230V with motor-protection and "duty standby assist" to automatically operate 2 pumps (each with a current rating of 6.3-10.0A). The dual pump panel is used in sump chamber installations and water supply systems where enhanced operational safety is required. Twin Sump Pump Control Panel | Duty Standby Assist A pump control panel with "duty standby assist" offers signficantly greater flexibility and uses the full potential of a dual pump installation setup. This allows to cover the performance level for standard operation as well as unusual high demand during e.g. freak precipitation events (drainage sump chamber) or higher water-supply demand (rainwater harvesting system). Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Duplex Alternating Pump Control Panel The dual pump control panel switches 2 pumps with alternating duty. The automatic switch-over after each pumping cycle ensures both pumps are used equally. In the event that motor-protection of one pump is triggered, the automatic supply is upheld with the remaining pump. Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Only one pump is in operation, while the other pump remains switched off. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Pump | Assist | Peak Load In order to use the remaining non-operative pump as backup support, the contacts marked "Peak Load" are available to connect an additional external switch (e.g. pressure switch or float switch). If the contacts are closed by the external switch device, the 2nd pump in standby is activated additionally to assist the 1st pump. The assist function via the contacts "Peak Load" is an optional extra and does not have to be used! Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Pressure Switch / Float Switch; Peak Load Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED for respective pump & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the dual pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 1x pump | Duty Standby400V | 3Ph | 50 Hz | max. P2: > 0.75 kW | A: 1.6 - 2.5 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with connected Pressure-Switch or Float-Switch Manual Pump Operation possible Dry-Run Protection with connected Float-Switch (low level)Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm)1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Single Pump Control Panel in 400V with motor-protection and "duty standby" to automatically operate 1 pump (with a current rating of 1.6-2.5A). The pump panel is used in sump chamber installations and water supply systems. Sump Pump Control Panel | Duty Standby A pump control panel with "duty standby" to automatically switch a submersible sump pump or water supply pump at wells or rainwater harvesting installations. Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Once the contact is opened pump operation ceases. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the single pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 1x pump | Duty Standby400V | 3Ph | 50 Hz | max. P2: > 1.10 kW | A: 2.5 - 4.0 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with connected Pressure-Switch or Float-Switch Manual Pump Operation possible Dry-Run Protection with connected Float-Switch (low level)Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm)1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Single Pump Control Panel in 400V with motor-protection and "duty standby" to automatically operate 1 pump (with a current rating of 2.5-4.0A). The pump panel is used in sump chamber installations and water supply systems. Sump Pump Control Panel | Duty Standby A pump control panel with "duty standby" to automatically switch a submersible sump pump or water supply pump at wells or rainwater harvesting installations. Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Once the contact is opened pump operation ceases. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the single pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 1x pump | Duty Standby400V | 3Ph | 50 Hz | max. P2: > 2.20 kW | A: 4.0 - 6.3 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with connected Pressure-Switch or Float-Switch Manual Pump Operation possible Dry-Run Protection with connected Float-Switch (low level)Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm)1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Single Pump Control Panel in 400V with motor-protection and "duty standby" to automatically operate 1 pump (with a current rating of 4.0-6.3A). The pump panel is used in sump chamber installations and water supply systems. Sump Pump Control Panel | Duty Standby A pump control panel with "duty standby" to automatically switch a submersible sump pump or water supply pump at wells or rainwater harvesting installations. Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Once the contact is opened pump operation ceases. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the single pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 2x pumps | Duty Standby Assist 400V | 3Ph | 50 Hz | max. P2: > 0.75 kW | A: 1.6 - 2.5 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with 2x connected Pressure-Switches /Float-Switches (Operation + Peak Load) Manual Pump Operation for each pump possible Alternating Duty: pump switch-over after each pumping cycle (equal operational hours for both pumps) Dry-Run Protection with connected Float-Switch (low level); contacts bridged ex works Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm for each pump Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm) 1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Twin Pump Control Panel in 400V with motor-protection and "duty standby assist" to automatically operate 2 pumps (each with a current rating of 1.6-2.5A). The dual pump panel is used in sump chamber installations and water supply systems where enhanced operational safety is required. Twin Sump Pump Control Panel | Duty Standby Assist A pump control panel with "duty standby assist" offers signficantly greater flexibility and uses the full potential of a dual pump installation setup. This allows to cover the performance level for standard operation as well as unusual high demand during e.g. freak precipitation events (drainage sump chamber) or higher water-supply demand (rainwater harvesting system). Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Duplex Alternating Pump Control Panel The dual pump control panel switches 2 pumps with alternating duty. The automatic switch-over after each pumping cycle ensures both pumps are used equally. In the event that motor-protection of one pump is triggered, the automatic supply is upheld with the remaining pump. Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Only one pump is in operation, while the other pump remains switched off. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Pump | Assist | Peak Load In order to use the remaining non-operative pump as backup support, the contacts marked "Peak Load" are available to connect an additional external switch (e.g. pressure switch or float switch). If the contacts are closed by the external switch device, the 2nd pump in standby is activated additionally to assist the 1st pump. The assist function via the contacts "Peak Load" is an optional extra and does not have to be used! Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Pressure Switch / Float Switch; Peak Load Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED for respective pump & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the dual pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 2x pumps | Duty Standby Assist 400V | 3Ph | 50 Hz | max. P2: > 1.10 kW | A: 2.5 - 4.0 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with 2x connected Pressure-Switches /Float-Switches (Operation + Peak Load) Manual Pump Operation for each pump possible Alternating Duty: pump switch-over after each pumping cycle (equal operational hours for both pumps) Dry-Run Protection with connected Float-Switch (low level); contacts bridged ex works Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm for each pump Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm)1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Twin Pump Control Panel in 400V with motor-protection and "duty standby assist" to automatically operate 2 pumps (each with a current rating of 2.5-4.0A). The dual pump panel is used in sump chamber installations and water supply systems where enhanced operational safety is required. Twin Sump Pump Control Panel | Duty Standby Assist A pump control panel with "duty standby assist" offers signficantly greater flexibility and uses the full potential of a dual pump installation setup. This allows to cover the performance level for standard operation as well as unusual high demand during e.g. freak precipitation events (drainage sump chamber) or higher water-supply demand (rainwater harvesting system). Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Duplex Alternating Pump Control Panel The dual pump control panel switches 2 pumps with alternating duty. The automatic switch-over after each pumping cycle ensures both pumps are used equally. In the event that motor-protection of one pump is triggered, the automatic supply is upheld with the remaining pump. Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Only one pump is in operation, while the other pump remains switched off. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Pump | Assist | Peak Load In order to use the remaining non-operative pump as backup support, the contacts marked "Peak Load" are available to connect an additional external switch (e.g. pressure switch or float switch). If the contacts are closed by the external switch device, the 2nd pump in standby is activated additionally to assist the 1st pump. The assist function via the contacts "Peak Load" is an optional extra and does not have to be used! Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Pressure Switch / Float Switch; Peak Load Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED for respective pump & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the dual pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).
Pump Control Panel for the operation of 2x pumps | Duty Standby Assist 400V | 3Ph | 50 Hz | max. P2: > 2.20 kW | A: 4.0 - 6.3 | IP 63 Dimensions: 318 x 267 x 167 mm Automatic operation with 2x connected Pressure-Switches /Float-Switches (Operation + Peak Load) Manual Pump Operation for each pump possible Alternating Duty: pump switch-over after each pumping cycle (equal operational hours for both pumps) Dry-Run Protection with connected Float-Switch (low level); contacts bridged ex works Motor-Protection; Overload Protection, Short Circuit Protection, Phase-Malfunction Protection LED Display for Pump Operation and Alarm for each pump Cable connections: 4 x M20 & 4 x M25 1x Alarm Input: via external switching device (optional; e.g. float-switch for high-level alarm) 1x Alarm Output: potential-free for BMS 1x Status (System OK) Output: potential-free for BMS 1x Alarm Output: 230V/4.0A for external Alarm (Buzzer, Light) Lockable ON/OFF Switch RESET Button CE | WEEE | Made in Germany Twin Pump Control Panel in 400V with motor-protection and "duty standby assist" to automatically operate 2 pumps (each with a current rating of 4.0-6.3A). The dual pump panel is used in sump chamber installations and water supply systems where enhanced operational safety is required. Twin Sump Pump Control Panel | Duty Standby Assist A pump control panel with "duty standby assist" offers signficantly greater flexibility and uses the full potential of a dual pump installation setup. This allows to cover the performance level for standard operation as well as unusual high demand during e.g. freak precipitation events (drainage sump chamber) or higher water-supply demand (rainwater harvesting system). Applications: sump pump chambers; drainage sump chambers, wastewater pump chambers sewage pumping stations water supply from tanks or wells rainwater harvesting systems Duplex Alternating Pump Control Panel The dual pump control panel switches 2 pumps with alternating duty. The automatic switch-over after each pumping cycle ensures both pumps are used equally. In the event that motor-protection of one pump is triggered, the automatic supply is upheld with the remaining pump. Pump | Duty Standby | Pump Operation The pumping cycle is activated when the contacts marked "Operation" are closed by an external switch such as a pressure switch or float switch. Only one pump is in operation, while the other pump remains switched off. The external switch connected to the contacts "Operation" determines automatic pump operation via the control panel. It is necessary/mandatory to connect a pressure switch / float switch (additional accessory) to enable automatic pump operation. Pump | Assist | Peak Load In order to use the remaining non-operative pump as backup support, the contacts marked "Peak Load" are available to connect an additional external switch (e.g. pressure switch or float switch). If the contacts are closed by the external switch device, the 2nd pump in standby is activated additionally to assist the 1st pump. The assist function via the contacts "Peak Load" is an optional extra and does not have to be used! Input Connections | Switching Voltage: 230V Pressure Switch / Float Switch; Operation Pressure Switch / Float Switch; Peak Load Float Switch; Dry-Run Protection (Low Level Float Switch) - contacts bridged ex works Float Switch; High Level Alarm (High Level Float Switch); external fault - does not interrupt pump operation! Alarms Motor-Protection; displayed via red LED for respective pump & all alarm outputs Dry-Run Protection; displayed via red LED within the RESET-Button & all alarm outputs High Level Alarm (external fault); displayed via all alarm outputs Output to Buidling Management System (BMS) Alarm Output: potential-free for BMS Status (System OK) Output: potential-free for BMS Furthermore, the dual pump control panel also has an alarm output in 230V (max. 4.0A) for an external optical or acoustic alarm (Buzzer, Light).